The PICOPROBE? MODEL 110H is a high performance microwave probe which incorporates our patented coaxial design techniques and has inherent low loss and low dispersion characteristics. Like all of our Picoprobe microwave probes, the Model 110H has customer-preferred features such as: individually spring loaded Beryllium-Copper tips which provide reliable contacts even when probing non-planar structures; direct viewing of probe tips for accurate positioning; and can be designed to almost any pitch and footprint. Smaller pitches and Ground-Signal-Ground footprints are recommended for optimum performance. Connection to the Model 110H is via a female 1.0 mm connector. Please contact our office for additional information regarding the performance specifications of the Model 110H Picoprobe.
FIGURE 2
Picoprobe? Model 110H Performance Data
:
Typical uncalibrated performance of a Model 110H-GSG-100-P while touching a 50 Ohm load on our CS-5 Calibration Substrate.
深圳市森東寶代理美國GGB全系列探針
以下是微波探針 model 110H系列
購買須知:
1、此款產(chǎn)品起拍量為一個
2、購買前請一定要咨詢客服,詢問是否有足夠的庫存,直接拍下付款者概不發(fā)貨
3、可開發(fā)票,詳情請咨詢客服
如需其他型號高頻探針,請點擊:
Model 40A (dc to 40 GHz / 2.9mm K connector input)
Model 50A (dc to 50 GHz / 2.4 mm connector input)
Model 67A (dc to 67 GHz / 1.85 mm V connector input)
Model 110H (dc to 110 GHz / 1.0 mm connector input)
Dual / Differential Microwave Probe 差分探針
Model 40M/50M/67M 低損耗探針(ultra low loss - dc to 40 GHz)
High Performance Microwave Probes
Model 110H
Durable
Patented Coaxial Design
DC to 110 GHz
Insertion loss 1.5 db (110H)
Return loss 15 db (110H)
Individually Spring-loaded Contacts
Utilizes the 1.0 mm female connector
FIGURE 1
The PICOPROBE? MODEL 110H is a high performance microwave probe which incorporates our patented coaxial design techniques and has inherent low loss and low dispersion characteristics. Like all of our Picoprobe microwave probes, the Model 110H has customer-preferred features such as: individually spring loaded Beryllium-Copper tips which provide reliable contacts even when probing non-planar structures; direct viewing of probe tips for accurate positioning; and can be designed to almost any pitch and footprint. Smaller pitches and Ground-Signal-Ground footprints are recommended for optimum performance. Connection to the Model 110H is via a female 1.0 mm connector. Please contact our office for additional information regarding the performance specifications of the Model 110H Picoprobe.
FIGURE 2
Picoprobe? Model 110H Performance Data
:
Typical uncalibrated performance of a Model 110H-GSG-100-P while touching a 50 Ohm load on our CS-5 Calibration Substrate.
Typical insertion loss of a Model 110H-GSG-100-P.
FIGURE 3